Life Monitor TOP-1800

Life Monitor  TOP-1800

Reviewable ECG waveforms, Maximum 240 hours reviewing graphic trends

Digital SpO2 technique, precise measurement for weak perfusion and finger shaking

Arrhythmia and S-T segment analysis and pacemaker detection

Protection against interference from defibrillation and electrosurgical Unit

Applicable to ICU, CCU, operation, adult, pediatrics and neonatal patient


l Full lead:       I, II, III, AVL, AVR, AVF and V
l Gain        5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
l Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
l Band width 0.05Hz-100Hz(3dB)
l Heart rate:
Scope:     15 times/minute to 300 times/minutes
Accuracy:     ±1 time/minute
l Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes
 with histogram during RR period.
l Arrhythmia :Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times
     of arrhythmia kept and with 10 seconds kept for each time.   
Accuracy: Error rate < 20%
Undetected rate < 20%
Analysis function should be started when using the above two kinds of function.
l ST section
Scope:     ±0.8mV
Precision : ??? ±0.05mV
l Detection scope: 0%-100%
    Accuracy      ±1%     90%-100%
                      ±2%     70%-89%
l Theory Electric oscillator
l Cuff gassing time   less than 15 seconds
l First-time gassing pressure: dynamic state 24kPa ???180 mmHg??? 
Manual selection: 9.3kPa ???70 mmHg??????13.3kPa ???100 mmHg??????16.0kPa
???120 mmHg???
18.6kPa ???140 mmHg??????20.0kPa ???150 mmHg??????21.3kPa ???160 mmHg??????
l Automatic detection period: 1 minute to 240 minutes
Stop size???1 min???1 min -10min???, 5min(10 min -30min), 10min(30 min -90min) and 30min???90 min -240min???
l Detection scope:
Systolic blood pressure: 4kPa -34kPa(30mmHg -255mmHg)
Diastolic pressure 2kPa -29.3kPa(15mmHg -220mmHg)
Mean pressure     2.7kPa???31.3kPa ???20mmHg???235mmHg???
l Detection accuracy
Static pressure: ±3mmHg
Pulse rate: ±2%
l Chest impedance method or concentration of carbon dioxide at end of respiration
l Scope of chest impedance method 0 time/minute – 100 minutes/minute
l Precision of chest impedance method     1 time/minute
l Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg??? 0.4%vol-9.9%vol
l Detection scope of respiration rate: 2 times/minute ->60 times/minute ???including baby???
l Detection precision of respiration rate: ±1 time/minute
l Single/double path
l Type: Vascular/surface temperature
l Scope: 20??????50???
l Accuracy ±0.2???
Invasive blood pressure (selected mating)
l Single/double path
l Type: direct and continuous detection
   Scope:   -6.67kPa(-50mmHg)—46.67kPa(350mmHg)
l Precision???        below 13.33kPa(100mmHg) ±0.27kPa(2mmHg) 13.33kPa(100mmHg) above ±2%
l Frequency response???    DC-12Hz
l Input resistance: not less than 500kΩ
l Sensitivity of sensor: 5μV/V/mmHg
l Motivation voltage???    5V (DC)
l Accuracy of sensor: ±2???

l Isolation voltage: 4 kV